| The Venues ... Stourbridge Town Hall
Technical Information |
| Sound Equipment/Systems |
| Performance System |
| |
There is a new (November
2003) sound system installed in the auditorium, a new control position
has been created at the rear of the balcony. |
| Control |
Allan and Heath GL2200 24:4:2 |
| Speakers |
Logic Systems
1 Pair LS15 (main)
1 Pair LS12 (balcony delays)
1 Pair IS7 (stalls delay)
3 IS6 (front stalls infill)
1 Pair 15 (sub bass)
1 Pair CM12 (foldback) |
| Amplification |
Work SP2800, SP1600 and SP950 |
| Ancillary Equipment |
BSS Sound Web (delays & processing)
BSS FCS 966 dual graphics (2)
Phonic DFX256 effects
Tascam MD350 mini disc player
Tascam CD160 Compact disc player
Tascam 202 Mkiii Cassette deck
Microphones - Shure SM58 (5), Shure BG 2.1 (1) AKG C451/CK8 (6), Sennheiser
hand held radio microphone
EMO D.I, boxes (2)
|
| Paging |
There is a custom built paging system
to a number of zones, this can be done from the box office (located
off the main foyer), the control room and the stage managers desk
(limited call zones from this location) |
| Communications |
| Headset Communications |
Areac custom built system with a master
control. (i.e. no individual control). There are 13 outlets around
the stage and auditorium. |
| Headsets |
Beyer DT108 single sided headsets (8)
Beyer DT109 double sided headsets (2) |
| Show Relay |
Custom built Areac system to the dressing
rooms props area (stage right) and foyer, with a paging facility from
the control room and the stage managers desk (stage left). |
| Stage Lighting |
| Power Supply |
3 Phase 100 amps per phase |
| Dimmers |
2 Strand Permus 24 (24@ 2.5Kw per circuit) |
| Control |
Strand MX48 (this is operated from
the rear of the balcony)
(There is also an old Tempus 2 group board that can be used for
focusing etc. that can be connected downstage left). |
| Lanterns (These are all rigged) |
Harmony 15/28 (18)
Harmony F (24)
PAR 64 (10)
Coda 3 (8)
Solo CSI followspots (2) |
| Addtional Power Supplies Available |
| |
There is a 3 phase 125amp per phase
supply available stage left; this is fitted with a CEE Form 125amp
socket outlet. In addition there is a single phase 32amp supply
available under the stage for additional sound equipment, this is
also fitted with a CEE Form single phase 32amp socket outlet.
These supplies are in addition to the ring main available on stage.
Note – All power supplies are protected by 30mA RCD protection. |
| Stage Facilities |
| Dimensions |
The stage is raked and surfaced with
boarding sheets, the stage floor is painted mid grey.
Proscenium opening - 9.14m x 4.88m,
Maximum stage depth - 9.14m
Stage height - 1.18m
Grid height – 9.14m
Wings maximum – 0.9m |
| Drapes/Masking |
The house tabs legs and border are wine
red in colour, the house tabs are electrically operated from stage
left, there are a pair of grey tabs mid-stage and a pair of black
tabs upstage with an off white cyclorama just behind the black tabs.
Both pairs of tabs are hand operated, (stage left). There are 4 black
borders and 4 pairs of black legs which make up the remaining masking. |
| Flying Facilities |
There is hemp flying from a gallery stage
left, there are a total of 16 hemp sets in place each with a maximum
safe working load of 150Kg however 11 of these are used to fly the
above legs, borders, cyclorama etc. There is a total grid safe working
load of 1 Ton (1.02 Tonnes), the existing bars and lanterns account
for approximately 480Kg, (this excludes the weight of the drapes which
are hanging). |
| Audio Visual Equipment |
| Projectors |
Kodak slide projectors (2)
Bell and Howell overhead projector (1) |
| Screens |
6ft square (2) |